It shows that er05 is a temperature sensing fault.solutionCheck whether the cable of the temperature sensor is loose.Common faults of air water heatersCommon fault one: the unit ju...

What is the fault of air source heat pump er05?

05/22/2024 17:18:00无线充新闻

It shows that er05 is a temperature sensing fault.

solution

Check whether the cable of the temperature sensor is loose.

Common faults of air water heaters

< br >

Common fault one: the unit just started, not running

< br >

Check: the unit is normal, and the start delay is 3 minutes after power on; When the operation is suddenly shut down and restarted, the startup is delayed for 3 minutes;

< br >

Solution: Normal.

< br >

Common fault two: the host heat absorption fin frosts

< br >

Check: defrosting probe failure or (measure) refrigerant content is missing, or capillary micro-blocked, dirty blocked, ice blocked.

< br >

Solution: Replace the defrosting probe; Charge the same type of refrigerant, vacuum if necessary, and then charge the capillary tube.