中文English
0.05无线充hanxin360 2024-05-22 19:29 80
1, constant current charging, that is, the current is certain, and the lithium iron phosphate battery voltage gradually increases with the charging process, according to the above...

3.2v lithium iron phosphate battery correct charging method?

05/22/2024 19:29:50无线充新闻

1, constant current charging, that is, the current is certain, and the lithium iron phosphate battery voltage gradually increases with the charging process, according to the above specifications generally with 0.2C current charging, when the battery voltage is close to the full voltage 4.2V, change the constant current charging to constant voltage charging. The process takes about five hours.

2, constant voltage charging, that is, the voltage is certain, and the current gradually decreases with the saturation degree of the cell, according to the specification, when the current is reduced to 0.01C, that is, 10mA, it is considered that the charge is terminated. After this process and the constant current charging time are added up, the total charging time should not exceed eight hours.

3, lithium iron phosphate battery charging temperature is best within 0-45℃, such a temperature is more conducive to the lithium ion battery chemical activity, making the charging efficiency is higher.

4. For the charger of lithium iron phosphate battery pack, it is best to use the special charger equipped by the manufacturer. Do not use other chargers of other models or charging voltage is not suitable.

5. After the lithium iron phosphate battery is charged, try to prevent it from being placed on the charger for more than 10 hours, if it is not used for a long time, the mobile phone and the lithium ion battery should be separated.

6, the charger can only protect the entire battery pack terminal voltage, the balance of the charging board is to ensure that each single overcharge and each single is full, can not stop the entire lithium iron phosphate battery pack charging because there is a cell full.

7, iron phosphate lithium ion battery to get the hand want to formally use, it is necessary to charge, because lithium-ion battery storage power can not be too full, too full will make its capacity loss.

Summary: The charging method of lithium iron phosphate batteries is different from that of ordinary lithium ion batteries. In recent years, portable electronic products are developing towards lightweight and ultra-miniaturization, and portable lithium iron phosphate batteries with excellent safety performance have begun to be used. Lithium-ion iron phosphate batteries should pay attention to waterproof and dustproof when used, so there can be no water in the storage place, which will affect the performance and service life of the battery.


Shallow discharge shallow charge is the best way for lithium battery, lithium iron phosphate battery is characterized by high temperature resistance and low temperature resistance, the number of cyclic charge and discharge is about 3000-5000 times, so if you want to improve the service life of lithium iron phosphate battery, you can start to recharge when the power is close to 20%, and charge to 98% when the charge ends, which will not cause the battery to overdischarge and overcharge. Best for the battery.


Lithium iron phosphate battery pack correct charging method. The lithium iron phosphate battery pack is rated at 3.2V. During the charging process, the full voltage is related to the charging current, when the current is 0.3C, 3.8V can be judged as full, if it is 0.1C, it can be considered full to 3.65V. The charge of lithium iron phosphate battery pack is recommended to use CCCV charging mode, that is, constant current before constant voltage.

< br >

Lithium iron phosphate battery pack correct charging method

< br >

The charge of lithium iron phosphate battery pack is recommended to use CCCV charging mode, that is, constant current before constant voltage. Constant current 0.3C is recommended. The recommended constant voltage is 3.65. that is, 0.3C current charge during the constant current process. When the battery voltage reaches 3.65V, 3.65V voltage constant voltage charge is adopted. When you charge with a balanced voltage power supply, you also need to look at the charging current, it is recommended not to charge with too high a voltage, adjust the voltage to ensure that the charging current is below 0.5C, which is good for the battery.

< br >

General lithium iron phosphate battery charging upper voltage 3.7~4V, discharge lower voltage 2~2.5V, comprehensive consideration of discharge capacity, discharge median voltage, charging time, constant current capacity percentage, safety of these 5 aspects, the use of constant current constant voltage charging scheme, for lithium iron phosphate battery pack, charging limit voltage set at 3.55 ~ 3.70V is more reasonable. The recommended value is 3.60 ~ 3.65V, and the lower discharge voltage is 2.2V~2.5V.

< br >

The charger of the lithium iron phosphate battery pack is different from the ordinary lithium battery. The maximum termination charge voltage of a lithium battery is 4.2 volts; The lithium iron phosphate battery pack is 3.65 volts. When the lithium iron phosphate battery pack is charged, it is a balanced charging board connected to the line, generally from both ends of the direct series overall charging, the charger voltage is greater than the battery pack voltage. The voltage of each single cell is detected by the wire, which is equivalent to a parallel voltage regulator, and the charging voltage of the single cell will not exceed the voltage regulator value, while the other single batteries continue to charge through the regulator bypass charging.